Nitrile Foam Insulation Tube

Nitrile Foam Insulation Tube

FIRSTFLEX TM Elastomeric Foam Rubber Insulation Pipe is mostly used in conserving energy and preventing condensation on large pipes, ducts (covers), vessels, tanks and equipment.

  • Fast Delievery
  • Quality Assurance
  • 24/7 Customer Service
Product Introduction

Product Features of FIRSTFLEX TM Nitrile Foam Insulation Tube:

1). Closed cell structure.

2). energy saving insulation.

3). fireproof insulation.

4). eco-friendly

5). anti-condensation

6) soft and flexible.


Overview of FIRSTFLEX TM Nitrile Foam Insulation Tube:

FIRSTFLEX TM Elastomeric Foam Rubber Insulation Pipe is mostly used in conserving energy and preventing condensation on large pipes, ducts (covers), vessels, tanks and equipment.

Its closed-cell structure creates exceptional thermal properties, so it could protect against moisture penetration and heat loss or gain within a -297F to +220F temperature range.


Facing: aluminum foil facing, self-adhesive, white facing.


Advantages of FIRSTFLEX TM Nitrile Foam Insulation Tube:

Easy for installation; Anti-moisture

CFCS free or HCFCS free

Good steam resistance permeated ability 

Prevent thermal conduction effectively owing to close cell structure.


Packing:

Packed in FIRSTFLEX Carton; OEM carton customized.


Application of FIRSTFLEX TM Nitrile Foam Insulation Tube:

HVAC Systems: Nitrile foam insulation tubes are used in heating, ventilation, and air conditioning (HVAC) systems to insulate both hot and cold water pipes, refrigerant lines, and air ducts. This helps maintain the desired temperature of conditioned air and ensures energy efficiency.

Plumbing and Domestic Water Systems: Nitrile foam insulation tubes are applied to plumbing pipes, including hot and cold water lines, to prevent heat loss, maintain hot water temperatures, and reduce the risk of freezing in cold climates.

Refrigeration and Chilled Water Lines: They are used in refrigeration systems, refrigerated storage areas, and chilled water pipes to maintain low temperatures and prevent condensation.

Industrial Process Piping: Nitrile foam insulation tubes are applied in industrial settings to insulate pipes that transport hot or cold fluids, such as chemicals, steam, or water. This ensures temperature stability, energy efficiency, and worker safety.

Oil and Gas Industry: Used in oil refineries, petrochemical plants, and offshore platforms to insulate pipes that carry various fluids, including oil, gas, and chemicals. Nitrile foam insulation is resistant to many chemicals, oils, and solvents, making it suitable for these applications.

Marine and Shipbuilding: Applied in the construction and maintenance of ships and vessels, nitrile foam insulation tubes provide insulation for pipes in engine rooms, cold storage areas, and various ship systems.

Acoustic Insulation: Nitrile foam insulation tubes are used to reduce noise transmission through pipes, enhancing overall acoustic comfort in commercial, industrial, and residential spaces.

Steam Systems: In industrial and commercial settings, nitrile foam insulation tubes are used to insulate pipes carrying steam, ensuring the efficient transfer of heat while reducing heat loss.

Food and Beverage Industry: Applied in food processing facilities to insulate pipes carrying hot water, steam, or refrigerants, maintaining product quality and energy efficiency.

DIY and Residential Applications: Homeowners and contractors use nitrile foam insulation tubes for DIY projects, including insulating pipes in homes, garages, and outbuildings to improve energy efficiency and prevent freezing.

Soundproofing: Used in various applications to dampen vibrations and reduce noise levels, creating a quieter environment in theaters, recording studios, and commercial spaces.

Appliance Manufacturing: Nitrile foam insulation tubes are applied in the manufacturing of appliances, such as refrigerators and freezers, to provide thermal insulation and improve energy efficiency.


Specifications of FIRSTFLEX TM Nitrile Foam Insulation Tube:

<td" colspan="3" style="box-sizing: border-box; padding: 0px; margin: 0px; line-height: 22px;">9mm thickness (1.8m/piece)

Outer Diameter of Seamless Tube

DN of Galva-nized Tube

Inner Diameter

15mm thickness (2m/piece)

20mm thickness (2m/piece)

25mm thickness (2m/piece)

30mm thickness (2m/piece)



(mm)


(mm)

Specif-ication (mm×mm)

pcs/ bag

pcs/ bag

speci-fication (mm×mm)

pcs/ bag

Specif-ication (mm×mm)

Pcs/ bag

Speci-fication (mm×mm)

pcs/ bag

Specifi-cation (mm×mm)



6

6×9

180

180









6

10

10×9

140

140

10×15

80

10×20

70






13

13×9

120

100

13×15

80

13×20

50




14

8

16

16×9

100

95

16×15

60

16×20

50






19

19×9

100

80

19×15

60

19×20

40




22

15

22

22×9

100

70

22×15

60

22×20

40

22×25

30

22×30

25


25

25×9

80

55

25×15

60

25×20

30

25×25

25

25×30

28

20

28

28×9

60

50

28×15

50

28×20

30

28×25

25

28×30

32


32

32×9

60

45








32


34




34×15

40

34×20

30

34×25

25

34×30


25

35

35×9

60

40











38×9

50

30









25

42

42×9

50

30









32

43

43×9

50

30

43×15

30

43×20

25

43×25

20

43×30


40

48

48×9

50

28

48×15

30

48×20

25

48×25

20

48×30



54

54×9

50

25









50

60

60×9

50

20

60×15

30

60×20

20

60×25

15

60×30

76

70

76




76×15

25

76×20

15

76×25

15

76×30

89

80

89






89×20

15

89×25

15

89×30

108


108






108×20

15

108×25

10

108×30


Technical Parameters of FIRSTFLEX TM Nitrile Foam Insulation Tube:

Property

Performance

Standard

Material

NBR/PVC

-

Cell Structure

Closed Cell

-

Temperature limits (°C)

-40 °C to +120 °C

-

Density Range

40kg/m3 -7Okg/m3

ASTM D1667

Thermal Conductivity ( 40˚C)

0.038 W/mK

ASTM C518

Water Absorption

2.98

ASTM D 3575-91

Water Vapour Permeability
perm/Max

0.19 Perm - in

ASTM E 96-95

Resistance to Ozone

Excellent

ASTM D 1149

Flammability

Self Extinguishing

ASTM D 635-91

Fire Performance

Class 0

ASTM E-84

Copper corrosion

Negligible

ASTM C665

Limited Oxygen Index

32%

ASTM D 2863 - 77

Fungi Resistance

Passed

ASTM G21/C1338

Flexibility

Excellent

ASTM D 1056-85